Abstract

In reinforced concrete framed structures exposed to high lateral loads, the performance of the beam to column joints has been acknowledged to have a significant impact on the overall behaviour of the structures. The present study conducted an experimental investigation on four 1/3rd scale Precast Concrete (PC) beam-to-column grouted cementitious billet connections subjected to reverse cyclic loading. Their performance was compared with a reference monolithic connection. The various precast connections studied are Billet with Dowel (BD) connection, Billet with Dowel-cleat Angle (BD-CL) connection, and Extended Billet with Dowel-cleat Angle (EBD-CL) connection. The ultimate load-carrying capacity, ductility factor, hysteretic behaviour, load ratio, energy dissipation, and stiffness degradation of the monolithic (MO) and precast (PC) specimens were studied, and a comparison of their performances was made. The results show that the EBD-CL connection has comparable ductility and strength.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.