Abstract
The amount and magnitude of absorption and scattering of stress waves in concrete, mainly due to internal friction and aggregate inclusions, may be different when concrete mix proportions vary. In this study, we investigate the effect of concrete composition on the measurements of self-calibrated surface wave transmission functions (TRFs) and spectral energy transmission ratios (SETRs) which are used for crack depth estimation in concrete slabs. A series of experiments is carried out on a range of concrete specimens having more realistic crack (not a notch). It is found that the self-calibrated TRFs are very sensitive to both the concrete composition and the crack depth. However, the SETR is less sensitive to the concrete composition and more sensitive to the changes of crack depths. In conclusion the spectral energy transmission method can be effectively used for crack depth estimation in concrete regardless of their material compositions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.