Abstract

A convenient reverse osmosis (RO) laboratory technique for rapid initial screening of anti-scalant performance is based on full recycling of concentrate and permeate to the feed vessel and observing the scale suppression effectiveness under different operating conditions. Once-through flow tests in which both permeate and concentrate are continuously withdrawn from the RO system simulate more closely actual plant conditions but are usually impractical as they require a large inventory of the feed solution. In the recycle mode of operation, the residence time of the anti-scalant in the system is increased. The objective of the present study was to investigate if the increased residence time leads to a deviation between results measured by the simple recycle technique with those obtained by the more elaborate once-through technique. A comparison between inhibition results observed in full recycle and once-through tests respectively was carried out in a continuous flow pilot RO system. Tests were performed w...

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.