Abstract

Cast NiAl alloyed with Cr, Pt, Pd, Ir and Ru was tested in 1-h cycles at 950°C under hot corrosion conditions and at 1150°C in oxygen. For comparison, Hf-doped NiAl variants and a cast NiPtAl alloy resembling the composition of commercial aluminide coatings were included. Cr was the only element that reduced hot corrosion attack of NiAl significantly. However, at higher temperatures, addition of Cr to Hf-doped NiAl accelerated the alumina scale growth rate and promoted spallation of the oxide scale. The results from initial detailed characterization indicate that rejection of chromium at the metal-oxide interface gives rise to the formation of chromium-rich precipitates in the alloy, which apparently modify its oxidation behavior. This suggests that for NiAl-based substrates, hot corrosion resistance and exceptional scale spallation resistance may be mutually incompatible goals.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.