Abstract
Long term oxidation tests were carried out with a high-Cr ferritic steel at 800°C and 900°C in simulated cathode and anode gas of a solid oxide fuel cell (air and an Ar/H2/H2O mixture respectively). It was found that with decreasing sample thickness the life time of the steel decreases due to breakaway phenomena. This effect is caused by faster exhaustion of the chromium reservoir from the bulk alloy in the case of thinner components. During air exposure the oxidation rates increase with decreasing specimen thickness and this has to be taken into account in the calculation of the Cr-reservoir exhaustion. This thickness dependence is not found during the exposures in simulated anode gas. Hence, especially for thin walled components, the oxidation rates in anode gas are substantially smaller and thus the life times are longer than during air exposure. The differences in oxidation behaviour in the two environments are discussed on the basis of scale formation mechanisms involving microcrack formation in the surface oxide scale and depletion of major and minor alloying additions in the bulk alloy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.