Abstract

Objective: To explore the role of closed extension tube in preventing airway leakage during artificial airway clearance. Methods: The test lung was connected with a ventilator for mechanical ventilation. The pressure parameters were set as 16/5, 20/6, 24/7, 28/8, 32/9 and 36/10 cmH2O(1 cmH2O=0.098 kPa), respectively. The circuit was connected with an open extension tube or a closed extension tube. The ventilator was set with different pressure parameters to observe the changes of airway pressure and tidal volume during airway clearance. Results: (1) The pressure parameters were set as 16/5, 20/6, 24/7, 28/8, 32/9 and 36/10 cmH2O, and the airway pressures (in cmH2O) of circuit connected with open extension tube were (15.94±0.27)/(4.81±0.04), (20.09±0.23)/(6.05±0.16), (23.89±0.41)/(6.94±0.06), (27.90±0.22)/(7.71±0.18), (31.92±0.13)/(8.74±0.12)and(35.65±0.31)/(9.72±0.07), respectively.Under the same ventilator pressure parameters, the airway pressures (in cmH2O) of circuit connected with close extension tube were (16.36±0.06)/(4.85±0.04), (20.54±0.26)/(6.44±0.12), (24.36±0.24)/(7.01±0.33), (28.69±0.25)/(8.07±0.08), (32.97±0.33)/(8.93±0.09), (37.34±0.29)/(9.75±0.08), respectively. The airway pressure of circuit connected with open extension tube was lower than that connected with closed extension tube(P<0.05);with the increase of the pressure setting of the ventilator, the difference of the airway pressure between the two extended tubes gradually increased. When the maximum inspiratory pressure of the ventilator was set 36 cmH2O, the difference reached 1.69 cmH2O. (2) The airway pressures (in cmH2O) dropped from (15.94±0.27)/(4.81±0.04), (20.09±0.23)/(6.05±0.16), (23.89±0.41)/(6.94±0.06), (27.90±0.22)/(7.71±0.18), (31.92±0.13)/(8.74±0.12), (35.65±0.31)/(9.72±0.07) to (13.42±0.4)/(3.15±0.14), (16.81±0.6)/(4.30±0.14), (20.22±0.5)/(5.48±0.45), (23.73±1.4)/(6.25±0.22), (24.78±0.7)/(7.13±0.21), (20.83±0.4)/(6.61±0.19)when the suction port of the open extension tube was opened (P<0.05);and the tidal volume (in L) also decreased from 0.328±0.004, 0.580±0.012, 0.621±0.003, 0.626±0.003, 0.615±0.003, 0.603±0.002 to 0.272±0.008, 0.416±0.051, 0.487±0.047, 0.396±0.116, 0.507±0.022, 0.508±0.079, respectively (P<0.05). The decrease of airway pressure and tidal volume gradually increased with the increase of ventilator setting pressure. When the ventilator setting parameter was 36/10 cmH2O, the decrease of airway inspiratory pressure was (14.82±0.51) cmH2O and the maximum reduction of tidal volume was (0.164±0.021)L. (3)The airway pressure (in cmH2O) was increased to(15.70±0.23)/(4.80±0.33), (19.01±0.81)/(5.71±0.34), (22.27±0.62)/(6.85±0.44), (25.35±2.09)/(7.94±0.16), (28.38±0.46)/(8.96±0.23), (33.34±0.71)/(9.71±0.25) when the suction tube was inserted from the suction port of the open extension tube in the open state, and the tidal volume (in L) was increased to 0.340±0.016, 0.563±0.020, 0.571±0.030, 0.556±0.026, 0.514±0.021, 0.512±0.031 as well.The airway pressure and tidal volume of the ventilation circuit were higher than those in the open state, but still lower than those in the closed state. Compared with the closed state of the suction port, the maximum pressure drop and tidal volume decrease were (3.53±0.46) cmH2O and (0.101±0.011) L, respectively. (4) The pressure of the ventilator was set between 16/5 cmH2O to 36/10 cmH2O. The airway pressure (in cmH2O) was decreased from (16.26±0.04)/(4.85±0.04), (20.74±0.15)/(6.42±0.11), (25.09±0.31)/(7.10±0.13), (29.38±0.24)/(8.17±0.09), (33.80±0.16)/(9.02±0.17), (37.89±0.19)/(9.83±0.07) to(16.36±0.06)/(4.85±0.04), (20.54±0.26)/(6.44±0.12), (24.36±0.24)/(7.01±0.33), (28.69±0.25)/(8.07±0.08), (32.97±0.33)/(8.93±0.09), (37.34±0.29)/(9.75±0.08), respectively during the insertion of the suction tube from the suction port of the closed extension tube, and the tidal volume (in L) was decreased from0.361±0.005, 0.592±0.003, 0.631±0.001, 0.642±0.007, 0.633±0.007, 0.626±0.08 to 0.335±0.005, 0.588±0.008, 0.631±0.002, 0.638±0.004, 0.628±0.004, 0.618±0.005.The maximum pressure change of the ventilation circuit was (0.83±0.27) cm H2O and the maximum tidal volume change was (0.008±0.006)L. The changes of airway pressure and tidal volume were significantly lower than those of ventilation circuit connected with open extension tube under the same pressure parameters. Conclusion: The connection of closed extension tube in mechanical ventilation circuit can reduce the airway leakage during artificial airway clearance, which is worthy of clinical recommendation.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call