Abstract

Objective The objective of the study was to determine how standard shoulder dystocia maneuvers affect delivery force and brachial plexus stretch. Study Design A 3-dimensional computer model of shoulder dystocia was developed, including both a fetus and a maternal pelvis. Application of suprapubic pressure, rotation of the infant's shoulders, and delivery of the posterior arm following shoulder dystocia were each modeled, and delivery force and brachial plexus stretch were predicted. Results Compared with lithotomy alone, all maneuvers reduced both the required delivery force and brachial plexus stretch. The greatest effect was seen with delivery of the posterior arm, which showed a 71% decrease in anterior nerve stretch (3.9% vs 13.5%) and an 80% decrease in delivery force. Conclusion The standard maneuvers met the objective of reducing the necessary delivery force compared with the lithotomy position alone. Brachial plexus stretch is also reduced when these maneuvers are used rather than continuing the delivery in lithotomy position.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.