Abstract

Industrial fans are subject to European Union energy labeling and Ecodesign requirements. By using more efficient industrial fans, Europe will save 34 TWh and avoid 16 million tones of CO2 emissions annually by 2020 [1]. In this paper, the effect of the clearance gap between the impeller and the volute, on the performance of a centrifugal fan was investigated using open source CFD software OpenFOAM [2]. An automized loop with RANS and data post-processing is set up using Matlab, for allowing a large number of parameter variations. We conducted numerical analysis for all operating points, where starting points are optimal impellers for the whole range of specific speeds [3], [4]. The effect of volute angle and geometrical parameters related to the tongue [5], on total pressure loss, static pressure recovery coefficient and on efficiency are presented.