Abstract

Chemical penetration enhancers (CPEs) are commonly added into transdermal patches to impart improved skin permeation of drug. However, significant unexplained variability in drug release kinetics in transdermal patches is possible as a result of the addition of CPEs; investigations into the underlying mechanisms are still limited. In the present study, a diverse set of CPEs was employed to draw broad conclusions. Solubility parameters of CPEs and acrylate pressure-sensitive adhesive were calculated by molecular dynamics simulation and Fedors group contribution method to evaluate drug-adhesive miscibility. CPE-adhesive interaction was characterized by FT-IR study, 13C NMR spectroscopy, and molecular docking simulation. Results showed that release enhancement ratio (ERR) of CPEs for zolmitriptan was rank ordered as isopropyl myristate > azone > Plurol Oleique® CC497 > Span® 80 > N-methylpyrrolidone > Transcutol® P. It was found that solubility parameter difference (Δδ) between CPE and adhesive was negatively related with ERR. It was proved that hydrogen bonding between CPE and adhesive would increase drug release rate, but only if the CPE showed good miscibility with adhesive. CPE like isopropyl myristate, which had good miscibility with adhesive, could decrease drug-adhesive interaction leading to the release of drug from adhesive.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.