Abstract
The geometry configuration of proton exchange membrane fuel cell (PEMFC) which is considered as a promising energy conversion device has great influence on PEMFC performance. In this paper, effect of channel-to-rib width ratio and relative humidity of reactant gas on the performance are compared based on two single PEMFCs. The EIS testing results below 50 A are given and analyzed. The results obtained from polarization curves, power density curves and EIS fitting results prove that: 1. Compared with cell 3:4, the anode high humidification has a greater addition to the performance of cell 1:1; 2. PEMFCs with different geometry configurations of flow field have their own suitable working condition ranges; 3. The charge transfer resistance is the dominating factor when current loading is below 2.0 A cm−2.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.