Abstract

The right atrium has a significantly higher capacitance than the left atrium, and this may affect the Doppler flow pattern across an atrial septal defect (ASD) in unilateral atrioventricular (AV) valve atresia. This Doppler flow pattern is often used to assess ASD adequacy in this setting. We studied the effect of atrial capacitance and ASD size on the trans-ASD Doppler flow pattern in an in vivo flow model of alternate left or right AV valve atresia (LAVVA and RAVVA). We assessed trans-ASD Doppler flow patterns using the max/min velocity ratio and mean interatrial pressure gradients (PGs). In both models, ASD flow rate correlated with mean trans-ASD PG, but for similar flow rates the slope was higher in the LAVVA model. In LAVVA, a persistent PG was consistently observed, with low max/min ratio (median, 1.46; range, 1.03-3.13), whereas in RAVVA, phasic flow was common (median, 8.0; range, 2.8-20). Because atrial capacitance affects mean PG and Doppler flow pattern across the ASD, we propose that the assessment of ASD adequacy in RAVVA should not rely on Doppler findings.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.