Abstract

We report on measurements of electroosmotic mobility in polymer microchannels and silica capillaries with and without the addition of a caged fluorescein dye to the buffer. For PMMA microchannels, the mobility was found to increase from (2.6 +/- 0.1) x 10(-4) cm2 V(-1) s(-1) to (4.6 +/- 0.1) x 10(-4) cm2 V(-1) s(-1) upon addition of 1.2 mmol/L of caged dye. For PC microchannels, the mobility increased from (4.3 +/- 0.2) x 10(-4) cm2 V(-1) s(-1) to (5.4 +/- 0.1) x 10(-4) cm2 V(-1) s(-1) upon addition of caged dye. For PDMS microchannels, the mobility increased from (4.3 +/- 0.2) x 10(-4) cm2 V(-1) s(-1) to (6.4 +/- 0.5) x 10(-4) cm2 V(-1) s(-1) upon addition of caged dye. For fused-silica capillaries, the mobility ((5.5 +/- 0.2) x 10(-4) cm2 V(-1) s(-1)) was unaffected by the addition of the caged dye.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.