Abstract

Abstract Electrochemical corrosion behavior of Alloy 800 (UNS N08800) in sulfate solution was compared in the presence and absence of potassium phosphate monobasic/sodium hydroxide (KH2PO4/NaOH) buffering reagent. Cathodic polarization, cyclic voltammetry, and electrochemical impedance spectroscopy were used to characterize the behavior of hydrogen peroxide (H2O2) reduction in buffered and unbuffered solutions. Open-circuit potential measurements, polarization resistance, electrochemical impedance spectroscopy, and potentiodynamic polarization were utilized to evaluate the corrosion behavior of Alloy 800 as affected by the buffer reagent. Results showed that reduction of H2O2 takes place at higher potentials and with lower charge-transfer resistance in buffered solutions. The Alloy 800 passive layer thickened in the presence of the buffering reagent and showed lower corrosion rate. The overall anodic potentiodynamic behavior was similar in both the buffered and unbuffered solutions. Because of its bufferi...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.