Abstract
For obtaining high quality of underwater welding repairing for nuclear power equipments, the influence of boric acid on metal transfer process of underwater flux-cored wire wet welding in boric acid solution is explored by an X-ray transmission system. The research results show that the mixed repelled globular transfer and solid short circuit transfer mode and the mixed repelled globular transfer and surface tension transfer mode are two kinds of main metal transfer modes during underwater welding in boric acid solution. The proportion of the mixed repelled globular transfer and surface tension transfer mode is increasing with the increasing of concentration of boric acid solution, which is caused by the difference of force condition of the droplet.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.