Abstract
Blood flow is believed to affect the thrombogenicity of extracorporeal circulation (ECC). The purpose of this study was to look at the relationship between blood flow and thrombogenicity in a rabbit model of ECC. Rabbits were anesthetized and systematically heparinized. Bilateral jugular cannulation was performed, and the animals were placed on venovenous ECC. The circuits were composed of 1 m of 1/4 inch size surgical grade polyvinylchloride (PVC) tubing. ECC was maintained for 4 hours. Three experimental groups were studied: a high flow group (n=7; flow rate: 30 ml/min/Kg), low flow group (n=7; flow rate: 10 ml/mg/Kg), and no ECC group (n=7). Platelet count, fibrinogen concentration, PaO2/FiO2, and postmortem findings were evaluated. Platelet consumption was higher with high flow, and fibrinogen consumption was higher with low flow.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.