Abstract Axial compressor performance with heat extraction via blade passage surfaces (compressor cooling) is compared to its adiabatic counterpart, using computational experiments and mean line modeling. For a multistage compressor with an adiabatic design point, results at fixed corrected rotor speed indicate that, if available, compressor cooling would (i) raise the overall pressure ratio (at a given corrected flow), (ii) raise the maximum mass flow capability, (iii) raise the efficiency, defined as the ratio of isentropic work for a given pressure ratio to actual shaft work, and (iv) provide rear stage choking relief at low corrected speed. In addition, it is found that, if available, cooling in the front stages is better than in the rear stages. This is primarily a thermodynamic effect that results from the fact that, for a given gas, the compression work required to achieve a given pressure ratio decreases as the gas becomes colder. Heat transfer considerations indicate that the engineering challenges lie in achieving high enough heat transfer rates to provide a significant impact to the compressor’s performance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.