Abstract

BackgroundTo assess the corneal stress-strain index (SSI), which is a marker for material stiffness and corneal biomechanical parameters, in myopic eyes.MethodsA total of 1054 myopic patients were included in this study. Corneal visualisation Scheimpflug technology was used to measure the SSI. Corneal biomechanics were assessed using the first and second applanation times (A1-and A2-times); maximum deflection amplitude (DefAmax); deflection area (HCDefArea); the highest concavity peak distance (HC-PD), time (HC-time), and deflection amplitude (HC-DefA); integrated radius (IR); whole eye movement (WEM); stiffness parameter (SP-A1;, biomechanically corrected intraocular pressure (BIOP); and Corvis biomechanical index (CBI). Scheimpflug tomography was used to obtain the mean keratometery (Km) and central corneal thickness (CCT). According to the spherical equivalent (SE) (low myopia: SE ≥ − 3.00D and high myopia: SE ≤ − 6.00D.), the suitable patients were divided into two groups.ResultsThe mean SSI value was 0.854 ± 0.004. The SSI had a positive correlation with A1-time ((r = 0.272), HC-time (r = 0.218), WEM (r = 0.288), SP-A1 (r = 0.316), CBI (r = 0.199), CCT (r = 0.125), bIOP (r = 0.230), and SE (r = 0.313) (all p-values<0.01). The SSI had a negative correlation with HCDefA (r = − 0.721), HCDefArea (r = − 0.665), HC-PD(r = − 0.597), IR (r = − 0.555), DefAmax (r = − 0.564), and Km (r = − 0.103) (all p-values<0.01). There were significant differences in SSI (t = 8.960, p<0.01) and IR (t = − 3.509, p<0.01) between the low and high myopia groups.ConclusionsIn different grades of myopia, the SSI values were lower in eyes with higher SEs. It indicates that the mechanical strength of the cornea may be compromised in high myopia. The SSI was positively correlated with the spherical equivalent, and it may provide a new way to study the mechanism of myopia.

Highlights

  • To assess the corneal stress-strain index (SSI), which is a marker for material stiffness and corneal biomechanical parameters, in myopic eyes

  • The SSI had a positive correlation with The first and applanation time (A1-time) ((r = 0.272), HCtime (r = 0.218), Whole eye movement (WEM) (r = 0.288), Stiffness parameter (SP-A1) (r = 0.316), Corvis biomechanical index (CBI) (r = 0.199), central corneal thickness (CCT) (r = 0.125), Biomechanically corrected intraocular pressure (bIOP) (r = 0.230), and spherical equivalent (SE) (r = 0.313)

  • In different grades of myopia, the SSI values were lower in eyes with higher SEs

Read more

Summary

Introduction

To assess the corneal stress-strain index (SSI), which is a marker for material stiffness and corneal biomechanical parameters, in myopic eyes. By using finite element models of wide ranges of geometries of human eyeballs affected by different levels of intraocular pressure, Eliasy et al [7] studied clinical data obtained from two large datasets of healthy participants. According to their algorithm, the study produced a material stiffness parameter-stress-strain index (SSI) as a new parameter does not show significant correlation with CCT and IOP. We aimed to determine the normative values in myopic patients and the effect of SSI on myopia and to assess its possible correlation with other corneal biomechanical parameters

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call