Abstract
Under normal operating conditions, piping systems in nuclear power plants (NPPs) are subject not only to internal pressure but also to bending loads induced by deadweight and thermal expansion [1]. Bending is thus considered to be an important factor in evaluating the integrity of defective piping components. Local wall-thinning due to flow-accelerated corrosion is a main degradation mechanism of carbon steel piping systems in NPPs [2], and the integrity evaluation of wall-thinned piping components has become an important issue [3]. This study investigated the effects of bending load on the failure pressure of wall-thinned pipe bends under internal pressure. Our previous study experimentally evaluated the bending load effects on the failure pressure of wall-thinned elbows under displacement controlled in-plane bending load [4], but the numbers of experimental data were insufficient to determine the effects of bending load on the failure pressure of wall-thinned pipe bends. Therefore, the present study systematically evaluates the effects of bending load on the failure pressure of wall-thinned pipe bends using parametric finite element analyses.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.