Abstract

Galvanized coating is used to prevent corrosion of reinforcing bars. Contrary to steel, this coating reacts with the surrounding aqueous phase of the cement paste and induces a delay in the hydration of the interfacial zone. This paper describes an experimental study of this effect on bond strength of the reinforcement. This effect is evaluated by testing specimens with smooth bars, ribbed bars placed in a horizontal or vertical position, or machined bars with different rib heights. The results indicate that the bond performance of galvanized bars depends on the failure zone of the concrete surrounding the reinforcement and on the time of testing. The type of bar and the rib height of the reinforcing bar are designated as the parameters affecting the bond failure of galvanized bars.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.