Abstract
The copper brazed joints were obtained by induction brazing using in situ synthetic high Sn content silver filler metals with different B contents and the effect of element B on the wettability of filler metals and microstructure and mechanical properties of the joints were studied. With the addition of element B, the spreading area of the filler metals on the copper increases. The microstructure of the joints mainly consists of silver-based solid solution and copper-based solid solution, and the distribution of silver-based solid solution in the brazing seam becomes dispersed with the addition of B. The width of the brazing seam increases significantly with the increase in B content. Meanwhile, the B element was mainly distributed in the Ag-based solid solution. The tensile strength firstly increased and then sharply decreased with B added. The maximum average tensile strength of 206.83 MPa was obtained with a 2% addition of B and the joint fracture pattern is a brittle fracture.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.