Abstract

A new overfire air (OFA) technology was proposed by the authors for a Foster Wheeler down-fired boiler, and a small-scale cold experimental system for a 660-MWe unit was established. The velocity field distribution was measured in the furnace to study the characteristics of single-phase flow in the furnace at different OFA nozzle angles. The furnace temperature and distributions of the O2 concentration and NO concentration at different OFA nozzle angles were simulated using Fluent 6.3.26, and the average temperature of the furnace outlet, the O2 and NOx concentrations and carbon content in the fly ash were calculated. As the OFA nozzle angle increased, the vertical penetration depth of OFA increased and the horizontal penetration depth of OFA gradually decreased. The carbon content in the fly ash and NOx concentration initially rose and then fell at the furnace outlet, and they were lowest when the OFA angle was set at 20°. Thus, according to the findings of this article, an optimized OFA angle of 20° was chosen.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.