Abstract

In this study, the effects of atmospheric pressure plasma cleaning on the outgassing characteristics of MgO deposited on plasma display panel(PDP) glass have been investigated as a function of outgassing temperature. After the cleaning of the MgO deposited glass with He/O2/Ar and He/O2/Ar/N2, the decrease of main outgassing species such H2O, CO2, CO, and H2 and the increase of secondary electron emission from the MgO surface could be observed, possibly due to the removal of organic materials incorporated on the MgO layer. As the cleaning by He/O2/Ar/N2 showed, a lower outgassing vapor pressure, is possibly due to a higher cleaning rate.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have