Abstract

Measurements of axial temperature and electron density have been carried out for Ar-H2 dc transferred arc-plasma columns under varying ambient-pressure conditions (100-760 torr). Optical emission spectroscopy has been used as the diagnostic tool. Temperature was determined by the relative intensity method using atomic hydrogen lines. The electron-density measurements were obtained from the Stark width of the Hs (486.13 nm) line. Possible deviation from local thermodynamic equilibrium (LTE) has been studied by using Hs transitions and by measuring the population factor using ArI (696.5 nm) transition. The nonideality along the plasma column has been studied using the electron-density data. The plasma approaches weakly nonideal conditions near substrate. The maximum deviation from LTE conditions also arises near the transferred anode substrate. With an increase in pressure, the volume of plasma approaches LTE.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.