Abstract

Statement of problemLimited data are available in the dental literature regarding the effect of ambient lighting on the consistency of color quantification in cross-polarized photography. PurposeThe purpose of this clinical study was to investigate the effects of ambient lighting conditions and postprocessing photograph calibration on color quantification in cross-polarized dental photography. Material and methodsTwelve volunteers with intact maxillary central incisors were recruited. Cross-polarized photographs were captured under light-emitting diode (LED), fluorescent ceiling, and natural lighting. The photographs were repeated after a 1-week interval, yielding a total of 72 photographs. The average Commission Internationale de l’Eclairage L∗a∗b∗ coordinates of the right central incisor were obtained with a software program before and after calibration by using a neutral gray reference card. The color difference (ΔE) values were calculated for each participant between the repeated photographs under the change and no change in illumination both before and after calibration. A 3-way repeated measures ANOVA was used to compare these values (α=.05). ResultsA statistically significant 3-way interaction was found between the illuminant type, change in illumination, and calibration (P<.001); however, all the ΔE values were within a clinically acceptable threshold (ΔE≤3.7). Before calibration, when photographs were captured under no change in illumination, LED lighting was found to have a significantly lower ΔE than fluorescent (P=.008) and natural and fluorescent lightings (P=.011), but when there was a change in illumination, no significant differences (P>.05) were found. After calibration, all the ΔE values were ≤1 and significantly lower than the values before calibration (P<.001). ConclusionsBoth the ambient illuminant type and change in illumination had minimal effects on ΔE. Calibration through the use of a neutral gray reference card was found to result in reduced and imperceptible color change (ΔE≤1) for all illuminant types.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.