Abstract

PurposeHeat exchangers working in cryogenic temperature ranges are strongly affected by heat ingression from the ambient. This paper aims to investigate the effect of ambient heat-in-leak on the performance of a three-fluid cross-flow cryogenic heat exchanger.Design/methodology/approachThe governing equations are derived for a three-fluid cross-flow cryogenic heat exchanger based on the conservation of energy principle. For given fluid inlet temperatures, the governing equations are solved using the finite element method to obtain exit temperatures of the three-fluid exchanger. The performance of the heat exchanger is determined using effectiveness-number of transfer units (e-NTU) method. In the present analysis, the amount of ambient heat-in-leak to the heat exchanger is accounted by two parameters Ht and Hb. The variation of the heat exchanger effectiveness due to ambient heat-in-leak is analyzed for various non-dimensional parameters defined to study the heat exchanger performance.FindingsThe effect of ambient heat in leak to the heat exchanger from the surrounding is to increase the dimensionless exit mean temperature of all three fluids. An increase in heat in leak parameter (Ht = Hb) value from 0 to 0.1 reduces hot fluid effectiveness by 32 per cent for an NTU value of 10.Originality ValueThe effect of heat-in-leak on a three-fluid cross-flow cryogenic heat exchanger is significant, but so far, no investigations are carried out. The results establish the efficacy of the method and throw light on important considerations involved in the design of such heat exchangers.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call