Abstract

This paper gives a brief overview of Semiconductor Schottky diode detector in response to α-particle irradiation. As α-particle are difficult to detect so we need a high resolution device for its detection. In this paper we have simulated a model of Si Schottky diode detector in Sentaurus TCAD Software. TCAD (Technology Computer Aided Design) simulation is a boon for the semiconductor devices. Using this tool we can simulate and design semiconductor devices and can generate simulation model to get the best optimum simulation results for semiconductor diode. Sentaurus TCAD supports wide range of semiconductor technologies from conventional to compound semiconductor detector. α-particles induced transient current pulse measurement were carried out on Si Schottky diode at (1) different temperature, (2) different energies of the incident α-particle and (3) different reverse bias of Schottky diode. Effect of temperature, incident α-particle and reverse bias on the generated αinduced transient current pulse were analyzed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.