Abstract

A comprehensive experimental investigation is intended to survey consequence of nanofluid on performance of sundry parallel flow heat exchangers with the same heat transfer surface area. An experimental setup including one double-pipe heat exchanger, two shell-and-tube heat exchangers with different tube passes, and one plate heat exchanger is designed and built to carry out the experiments. The experiments are performed under turbulent flow conditions using distilled water and Al2O3/water nanofluid with 0.2, 0.5, and 1% particle volume concentrations. Based on the results from this study, the double-pipe heat exchanger reflected the best outcomes in the heat transfer coefficient with a maximum enhancement of 26%, while only a 7% increment in the heat transfer coefficient is observed for the plate heat exchanger. On the other hand, minimum punishment for pressure drop of the working fluids due to adding the nanoparticles is observed in the plate heat exchanger at 1% volume concentration with a maximum value of 10%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.