Abstract

In this study, the effect of Al-doping on dosimetric properties of CaF2 was investigated. Al-doped CaF2 showed a radiophotoluminescence (RPL) peak at 750 nm after X-ray irradiation. The RPL intensity decreased with the increase of Al concentration and was less than that of undoped CaF2. The minimum detectable dose as the RPL dosimeter of 0.01% Al-doped CaF2 was 42 mGy. Al-doped CaF2 also indicated thermally stimulated luminescence (TSL) glow peaks at 225, 285, 387, and 436 °C. The wavelengths of TSL were 390 and 500 nm. The minimum detectable dose as the TSL dosimeter of 1% Al-doped CaF2 turned out to be 0.43 μGy which is comparable to commercial dosimeters.