Abstract

A 3D computational electromagnetic-thermal coupled analysis was performed to analyze the effects of auxiliary cooling fans, called air-gap fans, on winding cooling in a large-capacity, high-speed induction motor. A novel non-uniform iron loss distribution mapping method considering time and rotation period was introduced to provide more accurate thermal modeling. Winding cooling performance in the motor was calculated and evaluated by considering the variation in thermal-fluid characteristics and thermal flow resulting from the air-gap fans. Results showed that flow rate distributed to the air gap was increased as the stagnant flow disappeared near the air gap because of the air-gap fans. The convective heat transfer coefficient on the winding surface was enhanced by the increased velocity of the internal flow. The heat transfer coefficients at the winding surface and air gap were increased up to 31% and 90%, respectively, due to the increased flow rate. Total winding cooling performance was improved, on average, by 55% with front- and rear-side air-gap fans. For single fan performance, a rear-side air-gap fan was more effective than a front-side air-gap fan.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.