Abstract
Roche Diagnostics has issued new c-fas calibrators for its automated systems. These produce creatinine values that are more comparable with those obtained by high-performance liquid chromatography. However, this results in an underestimation of measured creatinine at concentrations below 155 micromol/L and an overestimation at concentrations above this value. Serum and urine creatinine concentrations were prospectively determined on samples from 60 patients using the new (compensated) and old (uncompensated) c-fas calibrators, and Passing-Bablok regression analysis was performed. The regression equations thus determined were then used retrospectively to determine the compensated creatinine results (i.e. those results that would have been obtained using the new calibrator) in those serum and urine samples analysed in the previous year using the old uncompensated c-fas calibrator. The compensated creatinine results were then used to estimate the glomerular filtration rate (GFR) by calculating creatinine clearance. This was done by using the formula: UV/Pt, in which U represents the urinary creatinine concentration (micromol/L), V the urinary collection volume (mL), P the serum creatinine concentration (micromol/L) and t the urinary collection time (min). It was also calculated using the abbreviated Modification of Diet in Renal Disease study group (MDRD) formula. The creatinine clearance as determined using either the UV/Pt calculation or the MDRD formula overestimated GFR by approximately 30% and approximately 50%, respectively, in normal individuals with a serum creatinine concentration below 155 micromol/L. However, in patients with mild to moderate renal failure (serum creatinine from 155 to 500 micromol/L), changes in creatinine clearances determined by the two procedures were minimal. When laboratories introduce this new, compensated calibrator into practice, it may be appropriate to discuss its potential impact with clinical staff who monitor patients using creatinine clearance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.