Abstract

Pressure transducers and accelerometers that make use of semiconductors strain gages or have strain gages diffused on a silicon diaphragm cannot be used with a bridge balance network if one wants to achieve thermal zero compensation. Thermal zero compensation is compensating for the change in output due to temperature only, and is typically +-1.5 percent of the full scale output for a temperature change of 100/sup 0/F. The reason for not using a balance network is the way in which the transducer is thermally compensated. There are two ways to obtain thermal zero compensation with a semiconductor transducer: either match each individual gage to each other, or trim one-half of the bridge to match the other half of the bridge. It is the latter that is easiest to do and the method the manufacturers use. The method is described.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.