Abstract

A variable U-value would be beneficial for a buildings thermal performance. One way to switch the U-value of a wall, insulated with nano-porous material, is to change the internal pressure of the insulation This paper present thermal conductivity measurements showing a possible variation around of 3 times for a fumed silica and less than 2 times for an aerogel blanket when the pressure was varied between 1 and 100kPa. The variation factor of 3 was used in building energy simulation of a Swedish office showing that a U-value which can be varied within that range can give a significant reduction energy demand. Especially when energy used for cooling is weighted as worse than energy used for heating.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.