Abstract
A variable U-value would be beneficial for a buildings thermal performance. One way to switch the U-value of a wall, insulated with nano-porous material, is to change the internal pressure of the insulation This paper present thermal conductivity measurements showing a possible variation around of 3 times for a fumed silica and less than 2 times for an aerogel blanket when the pressure was varied between 1 and 100kPa. The variation factor of 3 was used in building energy simulation of a Swedish office showing that a U-value which can be varied within that range can give a significant reduction energy demand. Especially when energy used for cooling is weighted as worse than energy used for heating.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.