Abstract

Abstract A method to measure “on site” programmed charges in EEPROM devices is presented. Electrical Scanning Probe Microscopy (SPM) based techniques such as Electric Force Microscopy (EFM) and Scanning Kelvin Probe Microscopy (SKPM) are used to directly probe floating gate potentials. Both preparation and probing methods are discussed. Sample preparation to access floating gate/oxide interfaces at a few nanometers distance without discharging the gate proves to be the key problem, more than the probing technique itself. Applications are demonstrated on 128 kbit EEPROMs from ST Microelectronics and 64 kbit EEPROMs from Atmel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.