Abstract
Introduction Friction measurements in orthodontics are often derived from models by using brackets placed on flat models with various straight wires. Dental arches are convex in some areas. The objectives of this study were to compare the frictional forces generated in conventional flat and convex dental arch setups, and to evaluate the effect of different archwires on friction in both dental arch models. Methods Two stainless steel models were designed and manufactured simulating flat and convex maxillary right buccal dental arches. Five stainless steel brackets from the maxillary incisor to the second premolar (slot size, 0.22 in, Victory, 3M Unitek, Monrovia, Calif) and a first molar tube were aligned and clamped on the metal model at equal distances of 6 mm. Four kinds of orthodontic wires were tested: (1) A. J. Wilcock Australian wire (0.016 in, GH and (2) 0.016 × 0.022 in, (3) 0.018 × 0.022 in, and (4) 0.019 × 0.025 in (3M Unitek GmbH, Seefeld, Germany). Gray elastomeric modules (Power O 110, Ormco, Glendora, Calif) were used for ligation. Friction tests were performed in the wet state with artificial saliva lubrication and by pulling 5 mm of the whole length of the archwire. Six measurements were made from each bracket-wire combination, and each test was performed with new combinations of materials for both arch setups (n = 48, 6 per group) in a universal testing machine (crosshead speed: 20 mm/min). Results and Conclusions Significant effects of arch model (P = 0.0000) and wire types (P = 0.0000) were found. The interaction term between the tested factors was not significant (P = 0.1581) (2-way ANOVA and Tukey test). Convex models resulted in significantly higher frictional forces (1015-1653 g) than flat models (680-1270 g) (P 0.05). Type 1 wire tended to create the least overall friction in both flat and convex dental arch simulation models.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: American Journal of Orthodontics & Dentofacial Orthopedics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.