Abstract

This study aimed to compare two commercially available off the shelf branched endografts for thoraco-abdominal aortic aneurysm (TAAA) repair, namely the E-nside (Artivion) and Zenith t-Branch (Cook Medical) devices. This multicentre retrospective study (2020 - 2023) included patients treated by branched endovascular aortic repair (BEVAR) for TAAA using the inner branched E-nside or the outer branched t-Branch. Endpoints were 30 day technical success and major adverse events (MAEs) as well as one year freedom from target vessel instability and main endograft instability. The study included 163 patients: 79 (307 target vessels) treated with E-nside and 84 (325 target vessels) with t-branch. Aneurysm extent was I - III in 91 patients (55.8%; 47% of E-nside and 66% of t-Branch) and IV in 72 patients (44.2%; 53% of E-nside and 34% of t-Branch) (p= .011). An adjunctive proximal thoracic endograft was used in 43% of E-nside vs. 69% of t-Branch (p < .001), with less frequent thoracic endografting (14% vs. 76%; p < .001) and shorter length of coverage (p= .024) in extent IV TAAA treated by E-nside. E-nside cases had shorter renal artery bridging lengths (66 ± 17 mm vs. 76 ± 20 mm; p < .010) and less frequent use of a distal bifurcated endograft (53% vs. 80%; p < .001). Comparing 30 day results, the mortality rate was 1% vs. 2% (p= .62), any MAE occurred in 18% vs. 21% (p= .55), the stroke rate was 3% vs. 0% (p= .23), and the elective spinal cord ischaemia rate was 5% vs. 8% (p= .40) for E-nside and t-Branch, respectively. At one year, freedom from target vessel instability was 96 ± 3% for E-nside and 95 ± 3% for t-Branch (p= .58), and freedom from endograft instability was 98 ± 2% vs. 97 ± 3% (p= .46), respectively. Both off the shelf devices provided excellent early and one year results. The E-nside may require shorter thoracic aortic coverage and bridging length for the renal arteries, and less frequent implantation of a concomitant proximal thoracic or distal abdominal bifurcated endograft. However, these aspects did not determine significant differences in clinical outcomes.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.