EDIPO is the new 12.5 T superconducting test facility that is being installed at CRPP in Villigen, Switzerland. It will be placed beside the existing test facility SULTAN. The main purpose of both facilities is testing samples for the ITER project. EDIPO will provide a uniform high field region of 1 m, i.e. longer than SULTAN's ( 45 cm). EDIPO includes the main magnet and a superconducting transformer to power it with a current up to 100 kA in the test sample. The energy stored in the dipole is 16 MJ and in the undesired event of a quench this energy must be safely extracted. A Quench Detection System (QDS) is required to trigger the quench protection system for both the dipole and the transformer. This paper describes the overall QDS from the conceptual design, components, manufacture and commissioning as well as interactions with related systems.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.