This work addresses the subject of efficient storage of computed tomography (CT) data with an emphasis on the quality of surfaces. Industrial dimensional metrology often requires high measurement accuracy and it is shown that this is retained using wavelet-based compression methods. The applied techniques include a tensor product wavelet transform and soft wavelet shrinkage. In these tests, performed on real objects, dimensional CT measurements of compressed and uncompressed volumes were compared. The necessary storage space was reduced significantly with a negligible loss of accuracy. The storage space required for a multi-sphere phantom was decreased to 4.7% (from 638 MB to 30 MB), with an average deviation below 1 μm from the original volume.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.