Abstract

The type-439 ferritic stainless steel tubing is typically used for a moisture separator reheater (MSR) in a nuclear power plant turbine system. MSR employ heavier wall tubing than that of other reheaters. Generally, service-induced damage can occur on the outside diameter surface of the type-439 ferritic stainless steel tubing, and the most typical damage mechanism is the vibration-induced tube-to-tube support plate (TSP) wear and the fatigue cracking. In this study, the optimized magnetic flux density of an eddy current probe for the inspection of type-439 stainless steel tubing has been analyzed, and a specific magnetic saturation probe was designed. We have successfully evaluated the capability of the magnetic saturation eddy current technique to detect and measure flaws in the type-439 stainless steel tubing of moisture separator reheater.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.