Abstract
This paper presents a non-destructive evaluation study on a radiator with cooling fins as a kind of complex shaped specimen. An eddy current testing method, namely multi-frequency excitation and spectrogram method, was employed to detect a removal of radiator cooling fin. Experimental results brought remarkable signal when a fin was removed. Furthermore, the authors discuss the relation between the fin signal and specimen thickness, and concludes the availability for the estimation of thickness of radiator structures.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.