Abstract

The relevant issue of metal level control in a mould of continuous casting machine (CCM) is improving the measurement accuracy when adding slag powders in a mould. The main disadvantage of the widely used radiometric metal level control devices (MLCDs) is the dependence of the output signal on the amount of slag in a mould. Eddy current (EC) sensor for metal level control is not sensitive to the slag. It detects metal level indirectly by temperature of copper mould wall, which is in contact with liquid metal. As a consequence, eddy current MLCD speed of response is limited to the time constant of thermal transient processes in a mould wall, which is insufficient to modern steel industry. This paper deals with a mould CCM metal level control method by means of the EC sensor based on signal detection from the liquid metal through a copper mould wall. The direct method provides required signal speed of response of eddy current MLCD in the case of steel casting with the slag.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.