Abstract
The velocity fluctuations in the immediate vicinity of a free interface were measured with a hot film anemometer. And mass transfer rates and eddy exposure times were analyzed by using the method of deterministic approach. These mass transfer rates were compared with the mass transfer rates by means of concentration measurements in the air-water system. The eddy exposure time distributions obtained from velocity data were skewed toward the lower time value. The contribution of eddies wi:h small exposure time was increased as the liquid became more turbulent. The mass transfer rates were mainly contributed by the Prandtl size eddies and even larger eddies. The mass transfer predictions by the single eddy model employing a deterministic method were in good agreement with the experimental results by independent measurements of concentration.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.