Abstract

Reductions in irradiation costs and increases in production rate have provided a continuing incentive for more efficient operation of the Hanford Piles. These improvements have been obtained by means of higher specific powers, greater water flow rates, and better water utilization. However, the extent of the improvements which can be made in this manner may be limited by such factors as tube and slug corrosion, slug stability, and graphite damage rates at higher operating temperatures. Water purification and pumping costs are also factors to be considered. New slug designs are being developed which may be capable of much higher specific power operation. Higher graphite temperatures may also prove feasible, but the water plant performance limitations for the present single pass cooling systems may prove much more expensive to relieve. The use of recirculating cooling water as a means of attaining higher temperature, higher power operation has received preliminary study. A preliminary economic evaluation of an operating area equipped for recirculation versus single pass cooling is needed to better determine the relative merits of the two cooling methods. This report presents the results of such an evaluation and discusses the direction of future development work in the field of pile cooling.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call