Abstract

This paper examines a case of sudden systolic pressure fall, tachycardia, low pulse pressure, and high pulmonary artery wedge pressure due to acute aortic insufficiency which was induced by an Amplatz left (AL-1) guide catheter used for better guide support during percutaneous transluminal coronary angioplasty of the right coronary artery. AL guide catheters can cause acute aortic insufficiency, of which practitioners should be aware when sudden hemodynamic collapse occurs.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.