Abstract

The current study assessed the acute effects of pacemaker optimization (PMO) on cardiac function using echocardiographic (ECHO) tissue Doppler imaging (TDI) in the post CRT setting. Data were analyzed from 50 consecutive patients clinically referred for PMO. Patients underwent a sequential ECHO/TDIguided PMO study to determine optimal pacemaker settings. In 34 of 50 patients a change in pacemaker settings was made because of an objective improvement in ECHO/TDI findings. Overall, significant improvements were observed for ECHO/TDI measures of systolic function (global systolic contraction score, p < 0.001; ejection time, p < 0.05), diastolic function (diastolic filling period, p < 0.01; mitral velocity-time integral,p < 0.05) and left ventricular (LV) dyssynchrony (standard deviation of time to peak displacement, p < 0.05). In most patients referred for chronic PMO, ECHO/TDI-guided PMO can be used to objectively improve cardiac systolic function, diastolic function and/or LV dyssynchrony.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.