Abstract

Recent studies suggest that cardiac resynchronization therapy through biventricular pacing (BVP) may be a promising new treatment for patients with advanced congestive heart failure (CHF). This method involves implantation of pacer leads into the right atrium (RA), right ventricle (RV), and coronary sinus (CS) in patients with ventricular dyssynchrony as evidenced by a bundle branch block pattern on electrocardiogram (ECG). Clinical trials are enrolling stable patients with ejection fractions (EF) </= 35%, left ventricular end-diastolic diameters (LVIDd) >/= 54 mm, and QRS duration >/=140 msec. We compared echocardiography features of these patients (group 1) with other patients with EF </= 35%, LVIDd >/= 54 mm, and QRS < 140 msec (group 2 = presumably no dyssynchrony). Nine hundred fifty-one patients with CHF, LVID 54 mm, EF 35% by echocardiography were retrospectively evaluated. One hundred forty-five patients remained after those with primary valvular disease, prior pacing systems, or chronic atrial arrhythmias were excluded. From this group of 145 patients, a subset of 50 randomly selected patients were further studied (25 patients [7 females, 18 males] from group 1, and 25 patients [7 females, 18 males] from group 2). Mean age group 1 = 75 years old, mean age group 2 = 67 years old. Mean QRS group 1 = 161 msec, mean QRS group 2 = 110 msec. Each group was compared for presence of paradoxical septal motion, atrial and ventricular chamber sizes, LV mass, LVEF, and RV systolic function. Of the initial group of 951 patients, 145 (15%) met inclusion criteria. In the substudy, 20/25 (80%) of group l and 7/25 (28%) of group 2 subjects had paradoxical septal motion on echo (Fisher's exact test, P = 0.0005). The t-tests performed on the other echocardiography variables demonstrated no differences in chamber size, function, or LV mass. Cardiac resynchronization therapy with BVP appears to target a relatively small population of our advanced CHF patients (15% or less). Although increasing QRS duration on ECG is associated with more frequent paradoxical septal motion on echo, it is not entirely predictive. Paradoxical septal motion on echo may therefore be more sensitive at identifying patients who respond to BVP. Further prospective studies are needed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.