Abstract

Transcatheter tricuspid valve-in-valve replacement (TVIV) is an emerging therapy for dysfunctional surgical valves in patients with congenital and acquired TV disease. The present study was performed to establish baseline quantitative data for echocardiographic and invasive parameters obtained pre- and immediately post-TVIV. Patients were drawn from the VIVID Registry. This study included two cohorts. The registry cohort included all patients entered in the VIVID registry through February 2017 who had both echocardiographic and invasively measured gradients across the TV. The focused cohort comprised a subset of patients from a single institution who had both pre- and post-TVIV echocardiogram images reviewed offline by a single investigator. The echocardiographic variables measured were based on published guidelines from the American Society of Echocardiography. Assessment of paired pre- and/or postimplant echocardiographic and invasive pressure measurements (n=199) showed reasonable correlation between mean TV gradient measured invasively with cardiac catheterization and noninvasively both pre- and post-TVIV (R=0.72, P<.001), although there was a bias toward the echocardiographic gradient being higher than the invasively measured gradient and sizable discrepancies were reported in several patients. In the focused cohort (n=42), the mean TV inflow gradient was 9.3±5.0mm Hg pre- and 5.6±2.3mm Hg post-TVIV (P<.001). The TV pressure halftime and TV:left ventricular outflow tract Doppler velocity index were 215±94 msec and 3.4±1.2, respectively, at baseline, and 170±44 msec and 2.4±0.6 post-TVIV. Both the Doppler velocity index and the TVE velocity correlated with the mean TV inflow gradient. This study provides benchmark data for the echocardiographic assessment of valve function after TVIV. In this population, the significance of an inflow gradient after TVIV should be interpreted in the clinical context. The appropriate threshold for defining dysfunction may differ from the levels proposed for assessment of native or newly placed surgical valves.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.