Abstract

It is shown that by using the conical diffraction mount existing echelle gratings can be used at grazing incidence to achieve high spectral resolution in the extreme UV and soft x rays. Design considerations for grazing incidence echelle spectrographs are examined, and two sample designs are discussed. The first, for use in the extreme UV has a primary mirror and an entrance slit to the spectrograph. The system has resolution of 10(4), operates at any wavelength longward of 100 A, and covers 30% of the spectrum at a single setting. The x-ray spectrograph uses objective gratings to obtain spectral resolution of 2.8 x 10(4) over any factor of 2 in wavelength. It operates to wavelengths as short as 4 A.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.