Abstract

A case is reported of a congested arm occurring during intravenous regional anaesthesia with a double cuff tourniquet in a female elderly patient suffcring from hypertension. The proximal cuff was apparently inflated adequately to 300 mmHg. Recent studies showed that the use of only the proximal tourniquet was associated with a risk of venous leakage. In elderly hypertensive patients, when intravenous regional anaethesia was necessary, one would be justified in inflating the two cuffs before injection of the local anaesthetic.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.