Abstract

Metrizamide (non-ionic, Nyegaard Co., Oslo, Norway), diatrizoate (ionic) and metrizoate (ionic) were selectively injected into the right or the left canine coronary artery. ECG was recorded and external defibrillation was performed whenever ventricular fibrillation occurred. During left coronary injections metrizamide prolonged the PQ and QT intervals less than did the diatrizoate. During right coronary injections metrizamide affected the QT interval less than either diatrizoate and metrizoate. During right coronary infusions metrizamide caused significantly fewer incidences of ventricular fibrillation than diatrizoate. In clinical coronary arteriography it is assumed that metrizamide would generate fewer AV blocks than diatrizoate and fewer incidences of ventricular fibrillation after right coronary injections than diatrizoate. Changes in the PQ and QT intervals during coronary arteriography can be used as tests to predict the safety of new contrast media.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.