Abstract
A glassy carbon electrode (GCE) has been modified by electrochemical oxidation in mild acidic media (0.1moll−1 H2SO4) and could be applied for individual and simultaneous determination of ascorbic acid (AA), dopamine (DA) and uric acid (UA). Oxidized GCE shows a single redox couple (E0′=−2.5mV) which is based on the formation functional groups during the electrochemical pretreatment process. Proposed GCE successfully decreases the over potentials for the oxidation process of these species (AA, DA and UA) comparing with bare GCE. The oxidized GCE has its own simplicity, stability, high sensitivity and possesses the potential for simultaneous determination of AA, DA and UA.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.